HACKER SAFEにより証明されたサイトは、99.9%以上のハッカー犯罪を防ぎます。
カート(0

Dell DSDSC-200 問題集

DSDSC-200

試験コード:DSDSC-200

試験名称:Dell SC Series Storage Professional Exam

最近更新時間:2024-05-04

問題と解答:全120問

DSDSC-200 無料でデモをダウンロード:

PDF版 Demo ソフト版 Demo オンライン版 Demo

追加した商品:"PDF版"
価格: ¥6599 

無料問題集DSDSC-200 資格取得

質問 1:
A client needs On Demand Data Progression to immediately move data from Tier 1 to Tier
2 when a replay is taken.
After enabling manual mode, which two attributes should the technician assign to a custom storage profile to meet this requirement? (Choose two.)
A. Tier 1 - RAID 10 Replay
B. Tier 2 - RAID 5/6 Writes
C. Tier 1 - RAID 10 Writes
D. Tier 2 - RAID 5/6 Replay
正解:B,C

質問 2:
What are two 1 Gb iSCSI best practices to set up and-to-end connectivity (servers, switch, and storage)? (Choose two.)
A. Spanning Tree
B. Unicast Storm Control
C. Flow Control
D. Jumbo Frame
正解:A,D
解説: (Topexam メンバーにのみ表示されます)

質問 3:
A customer has a newly installed storage array. The customer needs to proactively monitor and report storage utilization on a regular basis.
Which customizable, proactive tool should be configured to perform this task?
A. Enterprise Manager Automated Reporting
B. Storage Center Event Monitoring
C. Dell SupportAssist
D. Enterprise Manager Threshold Alerting
正解:D

質問 4:
An engineer is performing failover testing on an FC-attached, dual-controller SC8000 system.
The engineer notes that the customer's Windows 2008 R2 servers experience I/O errors.
The RHEL and ESX servers experience no problems.
A11 FC HBA timeouts are configured per Dell best practices.
The Windows servers that are experiencing issues have had no OS-level configuration changes related to SAN storage.
All servers use the same FC fabric.
What is causing the connectivity loss during failover?
A. NPIV is NOT enabled on Storage Center FC local ports.
B. The windows Disk TimeoutValue is NOT set correctly.
C. An incorrect OS type was selected when the Windows server objects were created.
D. The FC cables plugged into the Windows servers have RX and TX reversed.
正解:D

質問 5:
An engineer is testing controller failover on a newly installed Storage Center . Which process should the engineer use?
A. Start server IO to a volume, restart a controller, then rebalance ports and ensure no IO errors.
B. Start server IO to volumes owned on each controller, restart the controllers simutaneously. and ensure no IO error.
C. Start server IO to a volume, restart either controller, and ensure no IO errors are reported.
D. Start server IO to volumes owned on each controller, restart the controllers sequentially, and ensure no IO error.
正解:B

質問 6:
An engineer needs to configure a server.
The server is connected to a Storage Center via iSCSI using or more hardware iSCSI host bus adapters.
If connectivity is lost due to controller failover, the server needs to reconnect to the Storage Center iSCSI target ports.
Which HBA feature must be enabled to meet the requirement?
A. Spin Up Delay
B. ARP Redirect
C. MAC Spoofing
D. Delayed ACK
正解:B

質問 7:
An engineer updates the SCOS version from 6.5.x to 6.6.x on an SC4020 via ISO.
The engineer uses the following credentials: admin / admin.
The engineer calls Dell Support for final health checks and is informed that a newer SCOS 6.6.x version is available.
The engineer tries to perform another ISO update to the newest SCOS 6.6.x version.
The engineer is unable to log back in to the BMC interface to start the ISO update.
What should the engineer do to update the newest SCOS version via ISO?
A. request Dell Support to reset the expired admin password
B. downgrade Java to version 7 from version 8
C. use the login credentials root/ calvin in SCOS 6.6.x
D. update Java to version 8 to use the updated BMC interface
正解:C

質問 8:
A local Storage Array replicates to a remote Storage Array. A problem occurs oil the local
Storage Array, which causes the engineer to failover to the remote Storage Array. Once the problem is fixed, the engineer needs to fail back to the local Storage Array. When the engineer tries to fail back to the local Storage Array. NO volumes are available to fail back
What is the cause of the problem?
A. The Replication Restore Points need to be validated.
B. The local Storage Array is still running.
C. The remote Storage Array is still running.
D. XO Replication QoS definitions exist.
正解:A

一年間の無料更新サービスを提供します

君が弊社のDell DSDSC-200をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたDell DSDSC-200をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のDell DSDSC-200を持っていることを保証します。

TopExamは君にDSDSC-200の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。

Dell DSDSC-200 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • SC Series Installation & Configuration
トピック 2
  • Dell SC Series Professional Exam.
トピック 3
  • SC Series Planning

参照:https://partnerdirect.dell.com/sites/channel/en-em/documents/dell-training-and-certification-learning-path-083116a-server-launch.pdf

弊社は無料Dell DSDSC-200サンプルを提供します

お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料DSDSC-200サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのDSDSC-200問題集は自分に適するかどうか判断して購入を決めることができます。

DSDSC-200試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。

弊社のDell DSDSC-200を利用すれば試験に合格できます

弊社のDell DSDSC-200は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はDSDSC-200問題集の質問と答えが間違いないのを保証いたします。

DSDSC-200無料ダウンロード

この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のDell DSDSC-200を利用すれば、君は一回で試験に合格できます。

安全的な支払方式を利用しています

Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のDSDSC-200問題集は全部Credit Cardで支払われることができます。

領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。

弊社は失敗したら全額で返金することを承諾します

我々は弊社のDSDSC-200問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のDell DSDSC-200を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。

DSDSC-200 関連試験
DC0-160 - dell storage foundations exam
DC0-200 - Certified Server Professional Exam
DC0-261 - Dell Storage Networking Professional Exam - Version 2
DC0-140 - business continuance foundations
DC0-260 - Dell Certified Storage Networking Professional
連絡方法  
 [email protected] サポート

試用版をダウンロード

人気のベンダー
Apple
Avaya
CIW
FileMaker
Lotus
Lpi
OMG
SNIA
Symantec
XML Master
Zend-Technologies
The Open Group
H3C
3COM
ACI
すべてのベンダー
TopExam問題集を選ぶ理由は何でしょうか?
 品質保証TopExamは我々の専門家たちの努力によって、過去の試験のデータが分析されて、数年以来の研究を通して開発されて、多年の研究への整理で、的中率が高くて99%の通過率を保証することができます。
 一年間の無料アップデートTopExamは弊社の商品をご購入になったお客様に一年間の無料更新サービスを提供することができ、行き届いたアフターサービスを提供します。弊社は毎日更新の情況を検査していて、もし商品が更新されたら、お客様に最新版をお送りいたします。お客様はその一年でずっと最新版を持っているのを保証します。
 全額返金弊社の商品に自信を持っているから、失敗したら全額で返金することを保証します。弊社の商品でお客様は試験に合格できると信じていますとはいえ、不幸で試験に失敗する場合には、弊社はお客様の支払ったお金を全額で返金するのを承諾します。(全額返金)
 ご購入の前の試用TopExamは無料なサンプルを提供します。弊社の商品に疑問を持っているなら、無料サンプルを体験することができます。このサンプルの利用を通して、お客様は弊社の商品に自信を持って、安心で試験を準備することができます。