livechat
期間限定特別サービス、15%割引キャンペーン実施中、02:23:55において終了。お得な割引コード:TOPJP2025
HACKER SAFEにより証明されたサイトは、99.9%以上のハッカー犯罪を防ぎます。
カート(0

Huawei H19-402_V1.0 問題集

H19-402_V1.0

試験コード:H19-402_V1.0

試験名称:HCSP-Presales-Data Center Network Planning and Design V1.0

最近更新時間:2025-09-18

問題と解答:全543問

H19-402_V1.0 無料でデモをダウンロード:

PDF版 Demo ソフト版 Demo オンライン版 Demo

追加した商品:"PDF版"
価格: ¥6599 

無料問題集H19-402_V1.0 資格取得

質問 1:
Which of the following statements about the monitoring software NetEco1000U is correct? (Multiple choice)
A. Real-time monitoring of UPS working status and operation of UPS
B. Support USB, SNMP, MODUBUS network communication
C. Free of charge, download and use from Huawei Support website as needed
D. Multiple alarm reporting functions such as email alarm, SMS alarm, etc.
E. SMS alarm requires optional SMS modem
正解:A,B,C,D,E

質問 2:
Which manufacturers have 50KVA power modules? (Multiple choice)
A. Schneider
B. INVT
C. Emerson
D. Huawei
正解:A,B,C,D

質問 3:
Huawei NetCol5000 is designed mainly for medium and high density scenarios (>5kW/cabinet)
A. False
B. True
正解:B

質問 4:
What aspects of FusionModule800 require on-site survey? (Multiple choice)
A. Wiring method
B. Pipe routing
C. Length between inner and outer units
D. Length of the cable from AC to module
正解:A,B,C,D

質問 5:
Huawei 25KW half cabinet variable frequency air-cooled air conditioner, which of the following description is correct? (Multiple choice)
A. The UPS capacity requirement for a single air conditioner is 79.0kVA. If UPS5000E is used, at least two 40kVA power modules are required.
B. The capacity calculation of a single air conditioner with UPS is 1.251.732 full load current 380*0.8/0.9
C. The capacity calculation of a single air conditioner with UPS is 1.21.732 full load current 3800.8/0.9
D. If a group of air conditioners is connected to a UPS system, then the capacity requirement of a single UPS system should be multiplied by the number of air conditioners running simultaneously. For example, if there is a 5+1 cold backup configuration, the capacity requirement of a single air conditioner UPS system should be
E. The UPS capacity requirement for a single air conditioner is 15.8kVA. If UPS5000E is used, at least one 25kVA power module is required.
正解:C,D,E

質問 6:
FusionModule2000 integrated UPS has two configurations: single MCCB and dual ATS.
A. False
B. True
正解:B

質問 7:
Huawei's self-developed air conditioner has a 6kV lightning protection filter function, the highest in the industry
A. False
B. True
正解:B

質問 8:
UPS5000-A/E 400KVA and above models are divided into standard version and enhanced version.
The standard version is equipped with () isolation switch.
A. Bypass Input
B. Output
C. Main input
D. Repair
正解:D

質問 9:
The domestic power supply standard is 380v/50Hz.
A. False
B. True
正解:A

連絡方法  
 support@topexam.jp サポート

試用版をダウンロード

人気のベンダー
Apple
Avaya
CIW
FileMaker
Lotus
Lpi
OMG
SNIA
Symantec
XML Master
Zend-Technologies
The Open Group
H3C
3COM
ACI
すべてのベンダー
TopExam問題集を選ぶ理由は何でしょうか?
 品質保証TopExamは我々の専門家たちの努力によって、過去の試験のデータが分析されて、数年以来の研究を通して開発されて、多年の研究への整理で、的中率が高くて99%の通過率を保証することができます。
 一年間の無料アップデートTopExamは弊社の商品をご購入になったお客様に一年間の無料更新サービスを提供することができ、行き届いたアフターサービスを提供します。弊社は毎日更新の情況を検査していて、もし商品が更新されたら、お客様に最新版をお送りいたします。お客様はその一年でずっと最新版を持っているのを保証します。
 全額返金弊社の商品に自信を持っているから、失敗したら全額で返金することを保証します。弊社の商品でお客様は試験に合格できると信じていますとはいえ、不幸で試験に失敗する場合には、弊社はお客様の支払ったお金を全額で返金するのを承諾します。(全額返金)
 ご購入の前の試用TopExamは無料なサンプルを提供します。弊社の商品に疑問を持っているなら、無料サンプルを体験することができます。このサンプルの利用を通して、お客様は弊社の商品に自信を持って、安心で試験を準備することができます。
a