質問 1:Which two statements about the Security Fabric are true? (Choose two.)
A. All FortiGate devices in the Security Fabric must have bidirectional FortiTelemetry connectivity.
B. FortiGate uses FortiTelemetry protocol to communicate with FortiAnalyzer.
C. Only the root FortiGate collects network information and forwards it to FortiAnalyzer.
D. Branch FortiGate devices must be configured first.
正解:A,B
質問 2:View the exhibit, which contains the partial output of an IKE real-time debug, and then answer the question below.

Why didn't the tunnel come up?
A. The remote gateway's phase 1 configuration does not match the local gateway's phase 1 configuration.
B. The pre-shared keys do not match.
C. The remote gateway is using aggressive mode and the local gateway is configured to use man mode.
D. The remote gateway's phase 2 configuration does not match the local gateway's phase 2 configuration.
正解:A
質問 3:Examine the following partial output from two system debug commands; then answer the question below.


Which of the following statements are true regarding the above outputs? (Choose two.)
A. Kernel indirectly accesses the low memory (LowTotal) through memory paging
B. The unit is in kernel conserve mode
C. The Cached value is always the Active value plus the Inactive value
D. The unit is running a 32-bit FortiOS
正解:C,D
質問 4:Exhibits:


Refer to the exhibits, which contain the network topology and BGP configuration for a hub.
An administrator is trying to configure ADVPN with a hub-spoke VPN setup using iBGP. All the VPNs are up and connected to the hub. The hub is receiving route information from both spokes over iBGP; however, the spokes are not receiving route information from each other.
What change must the administrator make to the hub BGP configuration so that the routes learned by one spoke are forwarded to the other spokes?
A. Configure an individual neighbor and remove neighbor-range configuration.
B. Make the configuration of remote-as different from the configuration of local-as.
C. Change the router id to 10.1.0.254.
D. Configure the hub as a route reflector client.
正解:D
解説: (Topexam メンバーにのみ表示されます)
質問 5:What events are recorded in the crashlogs of a FortiGate device? (Choose two.)
A. A process crash.
B. Changes in the status of any of the FortiGuard licenses.
C. Configuration changes.
D. System entering to and leaving from the proxy conserve mode.
正解:A,D
解説: (Topexam メンバーにのみ表示されます)
質問 6:View the exhibit, which contains a screenshot of some phase-1 settings, and then answer the question below.

The VPN is up, and DPD packets are being exchanged between both IPsec gateways; however, traffic cannot pass through the tunnel. To diagnose, the administrator enters these CLI commands:

However, the IKE real time debug does not show any output. Why?
A. The debug shows only error messages. If there is no output, then the tunnel is operating normally.
B. The debug output shows phase 1 negotiation only. After that, the administrator must enable the following real time debug: diagnose debug application ipsec -1.
C. The debug output shows phases 1 and 2 negotiations only. Once the tunnel is up, it does not show any more output.
D. The log-filter setting was set incorrectly. The VPN's traffic does not match this filter.
正解:D
質問 7:A FortiGate's portl is connected to a private network. Its port2 is connected to the Internet. Explicit web proxy is enabled in port1 and only explicit web proxy users can access the Internet. Web cache is NOT enabled. An internal web proxy user is downloading a file from the Internet via HTTP. Which statements are true regarding the two entries in the FortiGate session table related with this traffic? (Choose two.)
A. Both session have the local flag on.
B. The destination IP addresses of both sessions are IP addresses assigned to FortiGate's interfaces.
C. One session has the proxy flag on, the other one does not.
D. One of the sessions has the IP address of port2 as the source IP address.
正解:A,D
質問 8:A FortiGate device has the following LDAP configuration:

The LDAP user student cannot authenticate. The exhibit shows the output of the authentication real time debug while testing the student account:

Based on the above output, what FortiGate LDAP settings must the administer check? (Choose two.)
A. cnid.
B. dn.
C. password.
D. username.
正解:C,D
解説: (Topexam メンバーにのみ表示されます)
弊社のFortinet NSE7_EFW-7.0を利用すれば試験に合格できます
弊社のFortinet NSE7_EFW-7.0は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNSE7_EFW-7.0問題集の質問と答えが間違いないのを保証いたします。

この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のFortinet NSE7_EFW-7.0を利用すれば、君は一回で試験に合格できます。
弊社は無料Fortinet NSE7_EFW-7.0サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NSE7_EFW-7.0サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNSE7_EFW-7.0問題集は自分に適するかどうか判断して購入を決めることができます。
NSE7_EFW-7.0試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
TopExamは君にNSE7_EFW-7.0の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。
Fortinet NSE7_EFW-7.0 認定試験の出題範囲:
| トピック | 出題範囲 |
|---|
| トピック 1 | - Troubleshoot different operation modes for a FGCP HA cluster
- Troubleshoot web filtering issues
|
| トピック 2 | - Troubleshoot Autodiscovery VPN (ADVPN) to enable on-demand VPN tunnels between sites
- Troubleshoot central management issues
|
| トピック 3 | - Diagnose and troubleshoot connectivity problems using built-in tools
- Diagnose and troubleshoot resource problems using built-in tools
|
参照:https://nseti-pdfs.s3.us-west-2.amazonaws.com/desc/Enterprise_Firewall_7.0_Exam_Description.pdf
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNSE7_EFW-7.0問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のFortinet NSE7_EFW-7.0を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNSE7_EFW-7.0問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
一年間の無料更新サービスを提供します
君が弊社のFortinet NSE7_EFW-7.0をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたFortinet NSE7_EFW-7.0をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のFortinet NSE7_EFW-7.0を持っていることを保証します。