質問 1:A customer called you after a failure in their Microsoft Hyper-V environment on the "SVM1" SVM. The customer wants to enable nondisruptive operations (NDO) to prevent future failures.
In this scenario, which two actions must be performed? (Choose two.)
A. Verify that SMB3 is enabled.
B. Verify that the continuously-available option is set on the CIFS share.
C. Verify that SMB2 is enabled.
D. Verify that the branchcache option is set on the CIFS share.
正解:B,C
質問 2:Click the exhibit button.

A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?
A. Perfstat should be used to explain the behavior.
B. A case with NetApp should be raised to find the root cause.
C. The problem is due to a difference in operation size.
D. There are operation types that are not listed in the output.
正解:C
質問 3:Click the exhibit button.

A customer's system reported several errors. There was no disruption, but the customer is concerned about the system's health.
Referring to the exhibit, which statement is true?
A. One of the switches has failed.
B. Port 1D on the system has failed.
C. Storage redundancy is degraded.
D. One of the IOM modules on shelf 20 has failed.
正解:C
質問 4:An administrator wants to keep an automatic daily up-to-date copy of a volume at a disaster recovery location.
What should the administrator do to achieve this goal?
A. Configure a SyncMirror relationship to the remote location.
B. Perform a volume relocation to the remote location.
C. Configure a SnapMirror relationship to the remote location.
D. Perform an NDMP dump to the remote location.
正解:C
質問 5:A customer complains that the copy offload does not work when copying large file from a Windows 8 client between the CIFS shares that are hosted on the same ONTAP cluster.
What are two reasons for this problem? (Choose two.)
A. SMB 3.0 disabled on the CIFS SVM.
B. The client should be using Windows 10 for ODX support.
C. Deduplication is not enabled on the destination volume.
D. The source and target volumes reside on different cluster nodes.
正解:A,C
質問 6:Click the exhibit button.

The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit.
What is the reason for this error?
A. The requested OU Secure has incorrect principal and errored with
KRB5KDC_ERR_S_PRINCIPAL_UNKNOWN.
B. The administrator account password used in vserver cifs create was not entered correctly.
C. The syntax is incorrect; it should be vserver cifs create -cifs-server svm1 -domain example.com -ou ou=Secure, dc=example, dc=com.
D. The requested OU Secure does not exist in the Active Directory and must be created by the Active Directory administrator.
正解:A
質問 7:Click the exhibit button.

A storage administrator reports that when they enabled Vscan, they began receiving reports of CIFS users having very slow access to all their files. The storage administrator recovered from the issue by disabling Vscan on their SVM. The storage administrator was able to collect perfstat output during the time of the reported slow access, as shown in the exhibit.
In this situation, what is the problem?
A. Vscan server 10.23.23.54 was slower than Vscan server 192.168.100.144 in completing Vscan requests.
B. Vscan server 192.168.100.144 was slower than Vscan server 10.23.23.54 in completing Vscan requests.
C. The problem was with both Vscan servers 192.168.100.144 and 10.23.23.54.
D. The problem is on the SVM, as shown in the scan_latency output.
正解:B
弊社のNetwork Appliance NS0-592を利用すれば試験に合格できます
弊社のNetwork Appliance NS0-592は専門家たちが長年の経験を通して最新のシラバスに従って研究し出した勉強資料です。弊社はNS0-592問題集の質問と答えが間違いないのを保証いたします。

この問題集は過去のデータから分析して作成されて、カバー率が高くて、受験者としてのあなたを助けて時間とお金を節約して試験に合格する通過率を高めます。我々の問題集は的中率が高くて、100%の合格率を保証します。我々の高質量のNetwork Appliance NS0-592を利用すれば、君は一回で試験に合格できます。
安全的な支払方式を利用しています
Credit Cardは今まで全世界の一番安全の支払方式です。少数の手続きの費用かかる必要がありますとはいえ、保障があります。お客様の利益を保障するために、弊社のNS0-592問題集は全部Credit Cardで支払われることができます。
領収書について:社名入りの領収書が必要な場合、メールで社名に記入していただき送信してください。弊社はPDF版の領収書を提供いたします。
弊社は無料Network Appliance NS0-592サンプルを提供します
お客様は問題集を購入する時、問題集の質量を心配するかもしれませんが、我々はこのことを解決するために、お客様に無料NS0-592サンプルを提供いたします。そうすると、お客様は購入する前にサンプルをダウンロードしてやってみることができます。君はこのNS0-592問題集は自分に適するかどうか判断して購入を決めることができます。
NS0-592試験ツール:あなたの訓練に便利をもたらすために、あなたは自分のペースによって複数のパソコンで設置できます。
一年間の無料更新サービスを提供します
君が弊社のNetwork Appliance NS0-592をご購入になってから、我々の承諾する一年間の更新サービスが無料で得られています。弊社の専門家たちは毎日更新状態を検査していますから、この一年間、更新されたら、弊社は更新されたNetwork Appliance NS0-592をお客様のメールアドレスにお送りいたします。だから、お客様はいつもタイムリーに更新の通知を受けることができます。我々は購入した一年間でお客様がずっと最新版のNetwork Appliance NS0-592を持っていることを保証します。
Network Appliance NS0-592 認定試験の出題範囲:
| トピック | 出題範囲 |
|---|
| トピック 1 | - Demonstrate knowledge of troubleshooting ONTAP performance
- Describe the tools available for support or troubleshooting
|
| トピック 2 | - Demonstrate knowledge of hardware troubleshooting
- Demonstrate knowledge of how to handle panic events
|
| トピック 3 | - Demonstrate knowledge of troubleshooting SP or BMC
- Demonstrate knowledge of ONTAP cluster administration
|
| トピック 4 | - Demonstrate knowledge of the cluster interconnect infrastructure
- Describe software-defined ONTAP solutions
|
| トピック 5 | - Demonstrate knowledge of ONTAP NAS configurations
- Describe ONTAP performance concepts
|
参照:https://www.netapp.com/us/services-support/university/certification/ncse-ontap-specialist.aspx
弊社は失敗したら全額で返金することを承諾します
我々は弊社のNS0-592問題集に自信を持っていますから、試験に失敗したら返金する承諾をします。我々のNetwork Appliance NS0-592を利用して君は試験に合格できると信じています。もし試験に失敗したら、我々は君の支払ったお金を君に全額で返して、君の試験の失敗する経済損失を減少します。
TopExamは君にNS0-592の問題集を提供して、あなたの試験への復習にヘルプを提供して、君に難しい専門知識を楽に勉強させます。TopExamは君の試験への合格を期待しています。